Why a liver scan lists both kPa and dB/m

Reading a liver elastography report in Bali? Learn what stiffness and controlled attenuation measure, and which lines to match when comparing two scans.

Two measurements from one FibroScan. LSM · kPa: Stiffness of the tissue, used to assess fibrosis risk; CAP · dB/m: Ultrasound signal attenuation, used to assess steatosis; Follow-up: Compare the same measure and method on both original reports
A CAP reading is not an MRI liver-fat percentage. A clinician interprets each measurement alongside the examination details.

A liver clinic in Bali may hand you a FibroScan report with two prominent numbers. One carries the unit kPa and the other dB/m. They describe different properties of the liver. If you are following research about retatrutide and liver fat, a good place to start is the name and unit of the test on your own report. Numbers from different technologies can sound similar in a headline and still mean different things.

What each line of the printout measures

Liver stiffness measurement, often shortened to LSM, reflects how a mechanical wave travels through the tissue. The result is expressed in kilopascals, or kPa. Clinicians use stiffness as one piece of information when estimating the likelihood of fibrosis, which is scarring. A stiffness result is a physical measurement. Translating that figure into an estimate of fibrosis requires clinical interpretation.

The controlled attenuation parameter, usually shown as CAP, relates to the loss of ultrasound signal as it travels through tissue. It is expressed in decibels per metre, or dB/m. It helps estimate the presence or degree of steatosis, which means fat accumulation. CAP does not give the percentage of liver cells that contain fat. A percentage from an MRI fat-fraction study cannot simply be inserted where the report requests CAP. European liver, diabetes and obesity societies’ clinical guideline, Table 6.

What a comparison with biopsy actually established

Eddowes and colleagues studied people undergoing evaluation for suspected fatty liver disease. They assessed how well CAP distinguished grades of steatosis and how well stiffness measurements distinguished stages of fibrosis against a biopsy reference. That design asks whether each non-invasive measurement helps separate groups defined by tissue findings. It does not turn one reading into a microscopic view of an individual patient’s liver. Original diagnostic accuracy study.

An apparent disagreement between the two figures can be informative. A clinician looking at a CAP result is asking a different question from one reviewing a stiffness result. There is no medically meaningful combined “average” of kPa and dB/m. Nor does a difference of ten dB/m automatically mean ten per cent less liver fat. Keep the units attached to the values when sending a photograph or writing them in a message.

How to compare a scan in Bali with a previous scan

Bring the full reports from both clinics, including the examination name, date, units and any comments on measurement quality. Ask whether the same type of elastography was used. Two tests can both say “stiffness” and use kPa while relying on different methods with different interpretation thresholds. For follow-up, the European guideline notes that using the same method and device can reduce variation between examinations.

A useful question is whether the observed difference is large enough to change the clinician’s assessment or whether a repeat or another test is appropriate. Ask them to explain which line informs the fibrosis question and which informs the fat question. If you brought a retatrutide research article, highlight the investigators’ particular measurement. A laboratory value, an imaging result and a trial endpoint each belong on their own line in a medical history.